LV Switchgear Assemblies

POWER CONTROL CENTRES ( PCC)

Technical Data

Types Form II, III and IV
Assembly Fixed / Draw-out
Installation Indoor / Outdoor
Current rating Upto 5000A, 75kA for 1 Sec
Incomer device ACB / MCCB / SFU /ISOLATOR
Outgoing ACB / MCCB / SFU
Metering A, V, KW, Kwh, KVAh, PF, Hz etc as per request
Busbars High conductivity hard drawn tinned copper bars with colour coded fire retardant sleeves.
Enclosure E.G sheet steel, powder coated to RAL 7032 1.5/ 2mm thick. (Other specifications on request)

MOTOR CONTROL CENTRES ( MCC)

Technical Data

Types Form II, III and IV
Assembly Fixed / Draw-out
Installation Indoor
Current rating Upto 5000A, 75kA for 1 Sec
Incomer device ACB / MCCB / SFU /ISOLATOR
Outgoing ACB / MCCB / SFU
Metering A, V, KW, Kwh, KVAh, PF, Hz etc as per request
Busbars High conductivity hard drawn tinned copper bars with colour coded fire retardant sleeves.
Enclosure E.G sheet steel, powder coated to RAL 7032 1.5/ 2mm thick. (Other specifications on request)

METERING PANELS

Technical Data

Types Form II, III and IV
Assembly Fixed
Installation Indoor
Current rating Upto 2000A, 65kA for 1 Sec
Incomer device ACB / MCCB / SFU /ISOLATOR
Outgoing SFU/MCCB through meter & cutout
Metering A, V, KW, Kwh, KVAh, PF, Hz etc as per request
Busbars High conductivity hard drawn tinned copper bars with colour coded fire retardant sleeves.
Enclosure E.G sheet steel, powder coated to RAL 7032 1.5/ 2mm thick. (Other specifications on request)

AUTOMATIC POWER FACTOR PANELS ( APFC)

Technical Data

Types Form II
Assembly Fixed
Installation Indoor
Current rating Upto 1000KVAr
Incomer device ISOLATOR
Outgoing Capacitor banks backed up by HRC fuses controlled by microprocessor relay with capacitor duty contractors.
Number of Ckts Upto 14
Metering A, V, KW, Kwh, KVAh, PF, Hz etc as per request
Busbars High conductivity hard drawn tinned copper bars with colour coded fire retardant sleeves.
Enclosure E.G sheet steel, powder coated to RAL 7032 1.5/ 2mm thick. (Other specifications on request)

AUTOMATIC MAINS FAILURE PANELS ( AMF)

Technical Data

Types Form II
Assembly Fixed
Installation Indoor
Current rating Upto 1000KVAr
Incomer device ISOLATOR
Outgoing Capacitor banks backed up by HRC fuses controlled by microprocessor relay with capacitor duty contractors.
Number of Ckts Upto 14
Metering A, V, KW, Kwh, KVAh, PF, Hz etc as per request
Busbars High conductivity hard drawn tinned copper bars with colour coded fire retardant sleeves.
Enclosure E.G sheet steel, powder coated to RAL 7032 1.5/ 2mm thick. (Other specifications on request)

POWER CONTROL PANELS

  • Refrigeration and cold room panels
  • Sewage Treatment Plant Control Panels
  • Pump Control Panels
  • Control and Relay Panels
  • Street Light Control Panels