| Types | Form II, III and IV | 
| Assembly | Fixed / Draw-out | 
| Installation | Indoor / Outdoor | 
| Current rating | Upto 5000A, 75kA for 1 Sec | 
| Incomer device | ACB / MCCB / SFU /ISOLATOR | 
| Outgoing | ACB / MCCB / SFU | 
| Metering | A, V, KW, Kwh, KVAh, PF, Hz etc as per request | 
| Busbars | High conductivity hard drawn tinned copper bars with colour coded fire retardant sleeves. | 
| Enclosure | E.G sheet steel, powder coated to RAL 7032 1.5/ 2mm thick. (Other specifications on request) | 
LV Switchgear Assemblies
POWER CONTROL CENTRES ( PCC)
Technical Data

MOTOR CONTROL CENTRES ( MCC)
Technical Data
| Types | Form II, III and IV | 
| Assembly | Fixed / Draw-out | 
| Installation | Indoor | 
| Current rating | Upto 5000A, 75kA for 1 Sec | 
| Incomer device | ACB / MCCB / SFU /ISOLATOR | 
| Outgoing | ACB / MCCB / SFU | 
| Metering | A, V, KW, Kwh, KVAh, PF, Hz etc as per request | 
| Busbars | High conductivity hard drawn tinned copper bars with colour coded fire retardant sleeves. | 
| Enclosure | E.G sheet steel, powder coated to RAL 7032 1.5/ 2mm thick. (Other specifications on request) | 

METERING PANELS
Technical Data
| Types | Form II, III and IV | 
| Assembly | Fixed | 
| Installation | Indoor | 
| Current rating | Upto 2000A, 65kA for 1 Sec | 
| Incomer device | ACB / MCCB / SFU /ISOLATOR | 
| Outgoing | SFU/MCCB through meter & cutout | 
| Metering | A, V, KW, Kwh, KVAh, PF, Hz etc as per request | 
| Busbars | High conductivity hard drawn tinned copper bars with colour coded fire retardant sleeves. | 
| Enclosure | E.G sheet steel, powder coated to RAL 7032 1.5/ 2mm thick. (Other specifications on request) | 

AUTOMATIC POWER FACTOR PANELS ( APFC)
Technical Data
| Types | Form II | 
| Assembly | Fixed | 
| Installation | Indoor | 
| Current rating | Upto 1000KVAr | 
| Incomer device | ISOLATOR | 
| Outgoing | Capacitor banks backed up by HRC fuses controlled by microprocessor relay with capacitor duty contractors. | 
| Number of Ckts | Upto 14 | 
| Metering | A, V, KW, Kwh, KVAh, PF, Hz etc as per request | 
| Busbars | High conductivity hard drawn tinned copper bars with colour coded fire retardant sleeves. | 
| Enclosure | E.G sheet steel, powder coated to RAL 7032 1.5/ 2mm thick. (Other specifications on request) | 

AUTOMATIC MAINS FAILURE PANELS ( AMF)
Technical Data
| Types | Form II | 
| Assembly | Fixed | 
| Installation | Indoor | 
| Current rating | Upto 1000KVAr | 
| Incomer device | ISOLATOR | 
| Outgoing | Capacitor banks backed up by HRC fuses controlled by microprocessor relay with capacitor duty contractors. | 
| Number of Ckts | Upto 14 | 
| Metering | A, V, KW, Kwh, KVAh, PF, Hz etc as per request | 
| Busbars | High conductivity hard drawn tinned copper bars with colour coded fire retardant sleeves. | 
| Enclosure | E.G sheet steel, powder coated to RAL 7032 1.5/ 2mm thick. (Other specifications on request) | 

POWER CONTROL PANELS
- Refrigeration and cold room panels
- Sewage Treatment Plant Control Panels
- Pump Control Panels
- Control and Relay Panels
- Street Light Control Panels